Solar Hot Water for Industrial Laundries: Sizing, Boiler Preheating & ROI

2026/10/19 16:37


Solar Hot Water for Industrial Laundries: Sizing & ROI 2026

INDUSTRIAL SOLAR PREHEATING

Solar Hot Water for Industrial Laundries: Sizing, Boiler Preheating & ROI

SOLETKS Solar  ·  ENGINEERING APPLICATION GUIDE  ·  English technical resource

SOLETKS EFPC large-format blue flat plate solar thermal collector module
SOLETKS large-format flat plate collector product image.
Jump to a section

Quick answer: Yes — solar thermal works well for industrial laundries when it preheats incoming water before the existing boiler or steam heater.

Worked example:

  • Demand: A laundry washing 5 tonnes of linen a day in a tunnel washer uses about 15,000 litres of fresh water. Heating it from 15°C to 60°C takes about 785 kWh a day.

  • Solar share: Solar preheating to 40°C supplies about 436 kWh, or 56% of that heat.

  • Collector area: about 175–240 m² of flat plate collectors, depending on climate.

  • Savings: At the 2025 EU average business gas price, every 100,000 kWh of solar heat saves about €7,100 a year.

ItemValueSource
Fresh water, modern tunnel washerabout 2.3–3 L per kg linenPublic industry source
Fresh water, tuned washer-extractorabout 20 L per kgPublic industry source
Raw energy, washer-extractor laundries0.7–1.1 kWh per kgPublic industry source
Saving from wastewater heat exchangerup to 0.15 kWh per kgPublic industry source
Saving from 60–65°C instead of 85°C washingabout 0.1 kWh per kgPublic industry source
EU business gas price, H2 2025€0.0605 per kWh (€0.041–0.107 by country)Eurostat

Want a solar estimate for your laundry? Send SOLETKS your country, kg of linen per day (or litres of hot water), water temperatures and boiler type. We will estimate collector area, solar share and savings.Get a Laundry Solar Estimate on WhatsApp

1. Is Solar Hot Water Right for Your Laundry?

Solar thermal fits best when the laundry has:

  • Steady daily hot-water use, five or more days a week

  • Low-to-medium temperature preheating needs (incoming water at 10–20°C)

  • Roof or ground space of roughly 1 m² of collector for every 60–90 litres a day preheated by 25°C (see section 5)

  • An existing boiler or steam heater that can accept preheated water

  • A significant gas, oil or electricity bill for water heating

It fits poorly if the laundry runs only occasionally or already recovers most low-grade heat.

2. Where Laundry Heat Goes — and Where Solar Fits

ProcessTypical heat needSolar role
Washing (tunnel or washer-extractor)Hot water at 40–85°CBest fit: preheat fresh water
Hot water storageBuffer for wash cyclesSolar charges the tank
Boiler make-up waterTreated feedwaterPossible, needs boiler engineer review
Drying and ironingSteam or hot air at high temperatureUsually outside flat plate range

Solar does not replace the boiler. It reduces how much fuel the boiler burns to heat wash water.

3. How Much Hot Water Does an Industrial Laundry Use?

Water use depends mostly on the machine type:

MachineFresh water per kg dry linen
Modern tunnel washer (cotton)about 2.3 L/kg
Tunnel washer, rinse dilutionabout 3 L/kg
Well-tuned washer-extractorabout 20 L/kg
Untuned washer-extractor30–45 L/kg

So 5 tonnes a day needs about 15,000 litres in a tunnel washer, but 100,000+ litres in washer-extractors. Measure your own consumption before sizing anything.

4. Calculate the Heating Demand

For water:

Q (kWh) = litres × temperature rise (°C) × 0.001163

Example: 5 t/day tunnel laundry

InputValue
Fresh water15,000 L/day
Inlet temperature15°C
Process temperature60°C

Full heating: 15,000 × 45 × 0.001163 ≈ 785 kWh/day (about 0.16 kWh per kg of linen)

Solar preheating 15°C → 40°C: 15,000 × 25 × 0.001163 ≈ 436 kWh/day (56%)

Boiler tops up 40°C → 60°C: 15,000 × 20 × 0.001163 ≈ 349 kWh/day

This covers wash-water heating only. Total laundry energy, including drying and finishing, is much higher — about 0.7–1.1 kWh of raw energy per kg in washer-extractor plants.

5. How Many Collectors Do You Need?

Collector area = daily solar heat target ÷ useful heat per m² per day

How much heat a m² delivers depends on the climate. On the Solar Keymark reference sites, annual sunlight on the collector plane is:

Reference siteAnnual irradiation on collector plane
Athens1,765 kWh/m²
Würzburg (Germany)1,244 kWh/m²
Stockholm1,166 kWh/m²

One Solar Keymark-tested flat plate collector delivers 1,106 kWh a year per 1.69 m² unit in Würzburg at 50°C. That is about 650 kWh/m² a year, or 1.8 kWh/m² a day on average. Scaled to Athens sunlight, it is about 2.5 kWh/m² a day.

ClimateUseful heat per m² per dayArea for 436 kWh/daySOLETKS EFPC150 modules (15 m² each)
Sunny (Athens-like)about 2.5 kWhabout 175 m²12
Central Europe (Würzburg-like)about 1.8 kWhabout 240 m²16

These are annual averages. Summer output is higher and winter lower, so the solar share varies by season. A final design should use hourly simulation for your site.

Sources: Solar Keymark reference-site figures (third-party tested-collector example).

6. Three Ways to Connect Solar to Laundry Heating

SOLETKS dark flat plate solar thermal collector units photographed on a neutral background
SOLETKS flat plate solar thermal collector product image.
OptionLayoutWhen to use
A. Preheat before the water heaterCold water → solar preheat tank → existing heater → washersSimplest; best first step
B. Preheat before a steam-heated tankCold water → solar preheater → steam-heated tank → washersLaundries with steam boilers
C. Preheat boiler make-up waterMake-up water → solar → deaerator/boilerOnly with boiler engineer approval

For most laundries, Option A or B is easier and safer than touching boiler feedwater.

More on boiler integration: SOLETKS — Solar preheating for boilers.

7. Recover Wastewater Heat First

Laundry wastewater leaves warm. A heat exchanger can save up to 0.15 kWh per kg of linen, and low-temperature washing (60–65°C instead of 85°C) about 0.1 kWh per kg.

Do these first. Then size solar for what remains, so you do not count the same savings twice.

StageTemperatureHeat (15,000 L/day)
Wastewater heat recovery15°C → 25°C174 kWh
Solar preheating25°C → 40°C262 kWh
Boiler top-up40°C → 60°C349 kWh
Total15°C → 60°C785 kWh

Fraunhofer ISE's SoProW-Demo project studied exactly this sequence in industrial laundries: reduce demand, recover heat, then add solar process heat. Source: Fraunhofer ISE — SoProW-Demo.

Already have heat recovery? Send us its outlet temperature. SOLETKS will size the solar field for the remaining load only.Size Solar After Heat Recovery

8. SOLETKS Collectors for Laundries

Detail of the connection hardware on a SOLETKS flat plate solar collector installation
SOLETKS solar thermal collector connector detail.
ParameterEFPC115EFPC150
Gross area11.42 m²15.0 m²
Aperture area10.48 m²13.92 m²
Dimensions5,030 × 2,270 × 140 mm5,960 × 2,520 × 166 mm
Weight235 kg315 kg
Working pressure1.0 MPa1.0 MPa
Max operating temperature150°C150°C
Peak / rated efficiency0.79 / 0.660.81 / 0.68
Peak power8.28 kW11.26 kW

Source: SOLETKS commercial flat plate collectors.

Large modules suit laundries because the collector field is big and centralized. A 240 m² field is 16 EFPC150 modules instead of 120 small panels, which means fewer lifts and fewer pipe joints.

9. Thermal Storage

Laundries often wash most in the morning; collectors produce most around midday. A buffer tank shifts the heat.

Example: 10,000 litres stored between 30°C and 55°C holds 10,000 × 25 × 0.001163 ≈ 291 kWh — about two-thirds of one day's solar target in the example.

Design points: pressure and temperature rating, insulation, stratification, Legionella control if the water serves people, and access for cleaning.

10. Savings and Payback with Real Gas Prices

Gas saved = solar heat ÷ boiler efficiency. Saving = gas saved × gas price.

For 100,000 kWh of useful solar heat a year and an 85% efficient boiler (117,647 kWh of gas avoided):

Gas price (Eurostat, non-household, H2 2025)Annual saving
EU average: €6.05 per 100 kWhabout €7,100
Germany: €7.13 per 100 kWhabout €8,400
Sweden: €10.65 per 100 kWhabout €12,500
Bulgaria: €4.14 per 100 kWhabout €4,900

Source: Eurostat — Non-household gas prices, second half 2025.

Simple payback = installed cost ÷ (annual saving − extra operating cost). Large European solar thermal systems cost about €500–540 per m² installed (IEA SHC Task 52). Use your actual quotation for the investment.

11. Common Mistakes

MistakeBetter approach
Sizing solar on total laundry energySize only on the water-heating load
One temperature for every programCalculate each program separately
Ignoring wastewater heat recoveryDo it first, then size solar
Assuming solar replaces the boilerSolar preheats; the boiler stays
Choosing collectors on peak efficiencyCompare useful heat at your temperature
Oversizing the fieldSize for summer demand to avoid wasted heat

12. Monitoring After Installation

Measure solar loop flow and temperatures, a heat meter on delivered solar heat, boiler fuel use, hot water volume and pump electricity. Compare energy per kg of linen before and after.

13. What to Send for a Quote

ItemExample
LocationCountry and city
Linen per day5,000 kg
Hot water per day15,000 L
Temperatures15°C inlet, 60°C process
Heating sourceGas boiler, steam, heat pump
Shifts2 shifts, 6 days a week
SpaceRoof or ground area in m²
Heat recoveryYes / no, outlet temperature
Energy priceGas or electricity per kWh

Frequently Asked Questions

How much hot water does an industrial laundry use?

Modern tunnel washers use about 2.3–3 litres of fresh water per kg of linen. Tuned washer-extractors use about 20 L/kg, and untuned ones 30–45 L/kg.

How much energy does it take to heat laundry water?

Heating 15,000 litres from 15°C to 60°C takes about 785 kWh. That is about 0.16 kWh per kg of linen for a 5 t/day tunnel laundry.

How many solar collectors does a laundry need?

For 436 kWh/day of solar preheating, about 175 m² in a sunny climate or 240 m² in central Europe — 12 to 16 SOLETKS EFPC150 modules.

Can solar replace the laundry boiler?

No. Solar preheats water; the boiler still provides the final temperature, steam and backup.

Should I install wastewater heat recovery first?

Yes. It can save up to 0.15 kWh per kg of linen. Size solar for the heat that remains.

How much can solar save on gas?

Each 100,000 kWh of solar heat saves about €7,100 a year at the 2025 EU average business gas price, and about €12,500 in Sweden.

What collectors suit industrial laundries?

Large flat plate modules rated to 1.0 MPa and 150°C, such as SOLETKS EFPC115 or EFPC150, which reduce installation work on big fields.

Request a Solar Thermal Assessment for Your Laundry

Send SOLETKS country and city, daily linen or hot water volume, water temperatures and boiler type. We will estimate collector area, solar share and savings.

Contact SOLETKS Solar on WhatsApp

Email: export@soletksolar.com · Website: www.soletksolar.com


Sources & Further Reading

The laundry example uses stated assumptions. Per-m² yields are averages derived from Solar Keymark reference data; a project design needs site-specific simulation.

Related Products