Quick answer: Yes — solar thermal works well for industrial laundries when it preheats incoming water before the existing boiler or steam heater.
Worked example:
Demand: A laundry washing 5 tonnes of linen a day in a tunnel washer uses about 15,000 litres of fresh water. Heating it from 15°C to 60°C takes about 785 kWh a day.
Solar share: Solar preheating to 40°C supplies about 436 kWh, or 56% of that heat.
Collector area: about 175–240 m² of flat plate collectors, depending on climate.
Savings: At the 2025 EU average business gas price, every 100,000 kWh of solar heat saves about €7,100 a year.
| Item | Value | Source |
|---|---|---|
| Fresh water, modern tunnel washer | about 2.3–3 L per kg linen | Public industry source |
| Fresh water, tuned washer-extractor | about 20 L per kg | Public industry source |
| Raw energy, washer-extractor laundries | 0.7–1.1 kWh per kg | Public industry source |
| Saving from wastewater heat exchanger | up to 0.15 kWh per kg | Public industry source |
| Saving from 60–65°C instead of 85°C washing | about 0.1 kWh per kg | Public industry source |
| EU business gas price, H2 2025 | €0.0605 per kWh (€0.041–0.107 by country) | Eurostat |
Want a solar estimate for your laundry? Send SOLETKS your country, kg of linen per day (or litres of hot water), water temperatures and boiler type. We will estimate collector area, solar share and savings.Get a Laundry Solar Estimate on WhatsApp
1. Is Solar Hot Water Right for Your Laundry?
Solar thermal fits best when the laundry has:
Steady daily hot-water use, five or more days a week
Low-to-medium temperature preheating needs (incoming water at 10–20°C)
Roof or ground space of roughly 1 m² of collector for every 60–90 litres a day preheated by 25°C (see section 5)
An existing boiler or steam heater that can accept preheated water
A significant gas, oil or electricity bill for water heating
It fits poorly if the laundry runs only occasionally or already recovers most low-grade heat.
2. Where Laundry Heat Goes — and Where Solar Fits
| Process | Typical heat need | Solar role |
|---|---|---|
| Washing (tunnel or washer-extractor) | Hot water at 40–85°C | Best fit: preheat fresh water |
| Hot water storage | Buffer for wash cycles | Solar charges the tank |
| Boiler make-up water | Treated feedwater | Possible, needs boiler engineer review |
| Drying and ironing | Steam or hot air at high temperature | Usually outside flat plate range |
Solar does not replace the boiler. It reduces how much fuel the boiler burns to heat wash water.
3. How Much Hot Water Does an Industrial Laundry Use?
Water use depends mostly on the machine type:
| Machine | Fresh water per kg dry linen |
|---|---|
| Modern tunnel washer (cotton) | about 2.3 L/kg |
| Tunnel washer, rinse dilution | about 3 L/kg |
| Well-tuned washer-extractor | about 20 L/kg |
| Untuned washer-extractor | 30–45 L/kg |
So 5 tonnes a day needs about 15,000 litres in a tunnel washer, but 100,000+ litres in washer-extractors. Measure your own consumption before sizing anything.
4. Calculate the Heating Demand
For water:
Q (kWh) = litres × temperature rise (°C) × 0.001163
Example: 5 t/day tunnel laundry
| Input | Value |
|---|---|
| Fresh water | 15,000 L/day |
| Inlet temperature | 15°C |
| Process temperature | 60°C |
Full heating: 15,000 × 45 × 0.001163 ≈ 785 kWh/day (about 0.16 kWh per kg of linen)
Solar preheating 15°C → 40°C: 15,000 × 25 × 0.001163 ≈ 436 kWh/day (56%)
Boiler tops up 40°C → 60°C: 15,000 × 20 × 0.001163 ≈ 349 kWh/day
This covers wash-water heating only. Total laundry energy, including drying and finishing, is much higher — about 0.7–1.1 kWh of raw energy per kg in washer-extractor plants.
5. How Many Collectors Do You Need?
Collector area = daily solar heat target ÷ useful heat per m² per day
How much heat a m² delivers depends on the climate. On the Solar Keymark reference sites, annual sunlight on the collector plane is:
| Reference site | Annual irradiation on collector plane |
|---|---|
| Athens | 1,765 kWh/m² |
| Würzburg (Germany) | 1,244 kWh/m² |
| Stockholm | 1,166 kWh/m² |
One Solar Keymark-tested flat plate collector delivers 1,106 kWh a year per 1.69 m² unit in Würzburg at 50°C. That is about 650 kWh/m² a year, or 1.8 kWh/m² a day on average. Scaled to Athens sunlight, it is about 2.5 kWh/m² a day.
| Climate | Useful heat per m² per day | Area for 436 kWh/day | SOLETKS EFPC150 modules (15 m² each) |
|---|---|---|---|
| Sunny (Athens-like) | about 2.5 kWh | about 175 m² | 12 |
| Central Europe (Würzburg-like) | about 1.8 kWh | about 240 m² | 16 |
These are annual averages. Summer output is higher and winter lower, so the solar share varies by season. A final design should use hourly simulation for your site.
Sources: Solar Keymark reference-site figures (third-party tested-collector example).
6. Three Ways to Connect Solar to Laundry Heating

| Option | Layout | When to use |
|---|---|---|
| A. Preheat before the water heater | Cold water → solar preheat tank → existing heater → washers | Simplest; best first step |
| B. Preheat before a steam-heated tank | Cold water → solar preheater → steam-heated tank → washers | Laundries with steam boilers |
| C. Preheat boiler make-up water | Make-up water → solar → deaerator/boiler | Only with boiler engineer approval |
For most laundries, Option A or B is easier and safer than touching boiler feedwater.
More on boiler integration: SOLETKS — Solar preheating for boilers.
7. Recover Wastewater Heat First
Laundry wastewater leaves warm. A heat exchanger can save up to 0.15 kWh per kg of linen, and low-temperature washing (60–65°C instead of 85°C) about 0.1 kWh per kg.
Do these first. Then size solar for what remains, so you do not count the same savings twice.
| Stage | Temperature | Heat (15,000 L/day) |
|---|---|---|
| Wastewater heat recovery | 15°C → 25°C | 174 kWh |
| Solar preheating | 25°C → 40°C | 262 kWh |
| Boiler top-up | 40°C → 60°C | 349 kWh |
| Total | 15°C → 60°C | 785 kWh |
Fraunhofer ISE's SoProW-Demo project studied exactly this sequence in industrial laundries: reduce demand, recover heat, then add solar process heat. Source: Fraunhofer ISE — SoProW-Demo.
Already have heat recovery? Send us its outlet temperature. SOLETKS will size the solar field for the remaining load only.Size Solar After Heat Recovery
8. SOLETKS Collectors for Laundries

| Parameter | EFPC115 | EFPC150 |
|---|---|---|
| Gross area | 11.42 m² | 15.0 m² |
| Aperture area | 10.48 m² | 13.92 m² |
| Dimensions | 5,030 × 2,270 × 140 mm | 5,960 × 2,520 × 166 mm |
| Weight | 235 kg | 315 kg |
| Working pressure | 1.0 MPa | 1.0 MPa |
| Max operating temperature | 150°C | 150°C |
| Peak / rated efficiency | 0.79 / 0.66 | 0.81 / 0.68 |
| Peak power | 8.28 kW | 11.26 kW |
Source: SOLETKS commercial flat plate collectors.
Large modules suit laundries because the collector field is big and centralized. A 240 m² field is 16 EFPC150 modules instead of 120 small panels, which means fewer lifts and fewer pipe joints.
9. Thermal Storage
Laundries often wash most in the morning; collectors produce most around midday. A buffer tank shifts the heat.
Example: 10,000 litres stored between 30°C and 55°C holds 10,000 × 25 × 0.001163 ≈ 291 kWh — about two-thirds of one day's solar target in the example.
Design points: pressure and temperature rating, insulation, stratification, Legionella control if the water serves people, and access for cleaning.
10. Savings and Payback with Real Gas Prices
Gas saved = solar heat ÷ boiler efficiency. Saving = gas saved × gas price.
For 100,000 kWh of useful solar heat a year and an 85% efficient boiler (117,647 kWh of gas avoided):
| Gas price (Eurostat, non-household, H2 2025) | Annual saving |
|---|---|
| EU average: €6.05 per 100 kWh | about €7,100 |
| Germany: €7.13 per 100 kWh | about €8,400 |
| Sweden: €10.65 per 100 kWh | about €12,500 |
| Bulgaria: €4.14 per 100 kWh | about €4,900 |
Source: Eurostat — Non-household gas prices, second half 2025.
Simple payback = installed cost ÷ (annual saving − extra operating cost). Large European solar thermal systems cost about €500–540 per m² installed (IEA SHC Task 52). Use your actual quotation for the investment.
11. Common Mistakes
| Mistake | Better approach |
|---|---|
| Sizing solar on total laundry energy | Size only on the water-heating load |
| One temperature for every program | Calculate each program separately |
| Ignoring wastewater heat recovery | Do it first, then size solar |
| Assuming solar replaces the boiler | Solar preheats; the boiler stays |
| Choosing collectors on peak efficiency | Compare useful heat at your temperature |
| Oversizing the field | Size for summer demand to avoid wasted heat |
12. Monitoring After Installation
Measure solar loop flow and temperatures, a heat meter on delivered solar heat, boiler fuel use, hot water volume and pump electricity. Compare energy per kg of linen before and after.
13. What to Send for a Quote
| Item | Example |
|---|---|
| Location | Country and city |
| Linen per day | 5,000 kg |
| Hot water per day | 15,000 L |
| Temperatures | 15°C inlet, 60°C process |
| Heating source | Gas boiler, steam, heat pump |
| Shifts | 2 shifts, 6 days a week |
| Space | Roof or ground area in m² |
| Heat recovery | Yes / no, outlet temperature |
| Energy price | Gas or electricity per kWh |
Frequently Asked Questions
How much hot water does an industrial laundry use?
Modern tunnel washers use about 2.3–3 litres of fresh water per kg of linen. Tuned washer-extractors use about 20 L/kg, and untuned ones 30–45 L/kg.
How much energy does it take to heat laundry water?
Heating 15,000 litres from 15°C to 60°C takes about 785 kWh. That is about 0.16 kWh per kg of linen for a 5 t/day tunnel laundry.
How many solar collectors does a laundry need?
For 436 kWh/day of solar preheating, about 175 m² in a sunny climate or 240 m² in central Europe — 12 to 16 SOLETKS EFPC150 modules.
Can solar replace the laundry boiler?
No. Solar preheats water; the boiler still provides the final temperature, steam and backup.
Should I install wastewater heat recovery first?
Yes. It can save up to 0.15 kWh per kg of linen. Size solar for the heat that remains.
How much can solar save on gas?
Each 100,000 kWh of solar heat saves about €7,100 a year at the 2025 EU average business gas price, and about €12,500 in Sweden.
What collectors suit industrial laundries?
Large flat plate modules rated to 1.0 MPa and 150°C, such as SOLETKS EFPC115 or EFPC150, which reduce installation work on big fields.
Request a Solar Thermal Assessment for Your Laundry
Send SOLETKS country and city, daily linen or hot water volume, water temperatures and boiler type. We will estimate collector area, solar share and savings.
Contact SOLETKS Solar on WhatsApp
Email: export@soletksolar.com · Website: www.soletksolar.com
Sources & Further Reading
Fraunhofer ISE — SoProW-Demo · IEA SHC Task 64 — Solar process heat
Solar Keymark reference-site figures (third-party tested-collector example)
The laundry example uses stated assumptions. Per-m² yields are averages derived from Solar Keymark reference data; a project design needs site-specific simulation.