PVT vs Solar Thermal Collectors: Differences, Efficiency and Which to Choose
PVT vs Solar Thermal Collectors: Differences, Efficiency and Which to Choose
PVT hybrid panels and solar thermal collectors both turn sunlight into useful heat, so they are often compared on the same project. They are built for different jobs. Choosing the wrong one can leave you short of hot water, short of electricity, or paying for roof area you do not need.
The key difference: a solar thermal collector (flat plate or evacuated tube) converts sunlight into heat only, and is designed to deliver high thermal output at useful hot water temperatures. A PVT panel (photovoltaic-thermal) puts PV cells on top of a thermal absorber, so it produces electricity and heat from the same surface. PVT gives more total energy per square metre, but its heat is at lower temperatures. Solar thermal wins when you need lots of heat at 50°C and above; PVT wins when roof space is limited and you need both power and low-temperature heat, especially with a heat pump.

In this guide
How each technology works
Solar thermal collectors: heat only
A solar thermal collector has a selective absorber that captures as much solar radiation as possible and loses as little heat as possible. Fluid flowing through the absorber carries the heat to a storage tank or process.
Flat plate collectors use a selective-coated absorber under low-iron solar glass in an insulated frame. They are robust, cost-effective and well suited to domestic and commercial hot water and space heating.
Evacuated tube collectors place the absorber inside vacuum-insulated glass tubes. Heat loss is very low, so they keep good efficiency at higher operating temperatures and in cold weather.
For a deeper comparison of these two, read flat plate vs evacuated tube: which is better?
PVT panels: electricity and heat together
A PVT solar panel combines a PV laminate with a heat exchanger bonded to its back. The PV cells generate electricity as normal. The sunlight that the cells do not convert, most of it, becomes heat. Instead of being wasted, that heat is collected by water, glycol or air flowing behind the cells.
This has two benefits. First, you get usable heat from the same roof area. Second, the cells run cooler. Crystalline silicon cells lose roughly 0.3% to 0.45% of their power for every 1°C rise in cell temperature, so cooling them recovers part of the output a hot PV module would lose. Read more in What is a PVT solar panel? and Can PVT generate heat and electricity at the same time?
PVT panels come in several forms:
Uncovered (unglazed) liquid PVT: no extra glass cover. Best electrical output and ideal as a low-temperature heat source for heat pumps.
Covered (glazed) liquid PVT: an extra cover reduces heat loss for higher water temperatures, at some cost to electrical output.
Air-based PVT: heats air for ventilation, drying or space heating. See solar air collector vs air PVT.

PVT vs flat plate vs evacuated tube: comparison table
The figures below are typical ranges to show the differences between technologies. Actual performance depends on the product, climate, operating temperature and system design, so always compare certified test data for the specific models.
| Factor | PVT hybrid panel | Flat plate collector | Evacuated tube collector |
|---|---|---|---|
| Output | Electricity + heat | Heat only | Heat only |
| Best operating temperature | Low: roughly 15–45°C | Medium: roughly 40–70°C | Medium to high: roughly 50–100°C+ |
| Thermal output per m² | Lower, especially at higher temperatures | High | High, and best when the temperature gap to ambient is large |
| Electrical output | Similar to a PV module, often slightly higher due to cell cooling | None | None |
| Total energy per m² of roof | Highest | Medium | Medium |
| Cold-weather heat output | Low on its own; strong as a heat pump source | Good | Very good |
| Overheating / stagnation | Must be managed: high temperatures reduce PV output and stress the laminate | Needs normal stagnation design | Can reach very high stagnation temperatures |
| Typical applications | Heat pump systems, pool heating, DHW preheating, buildings with limited roof and high power demand | Domestic and commercial hot water, space heating, solar district heating | Hot water in cold climates, higher-temperature commercial and industrial heat |
| Investment per m² | Highest | Lowest | Medium |
Why operating temperature decides everything
The most important question in this comparison is: what temperature does your system really need?
Every collector loses more heat as its working temperature rises above the surrounding air. Solar thermal collectors are designed to keep these losses low, so they still deliver strong output when producing water at 55–65°C.
A PVT panel faces a trade-off. If you run it hot, two things happen together: the thermal efficiency falls because heat losses rise, and the electrical output falls because the cells get hotter. PVT therefore performs best when it delivers low-temperature heat and the system lifts that heat to the final temperature with a heat pump or a backup heater.
Rule of thumb: if most of your heat demand is above about 50°C and you have enough roof, solar thermal will usually deliver more useful heat per square metre. If your heat is needed below about 40°C, or a heat pump is part of the system, PVT becomes very attractive.
Pairing PVT with a heat pump is one of the strongest uses of the technology. The PVT field acts as a warm source for the heat pump, which raises its efficiency. Uncovered panels can even collect heat from the ambient air when the sun is weak. Learn more in integrating PVT panels with heat pumps.
When to choose solar thermal collectors
Flat plate or evacuated tube collectors are usually the right choice when:
Hot water is the main goal. Hotels, hospitals, dormitories, apartment buildings and factories with a steady daily hot water load.
You need temperatures of 50°C and above for domestic hot water, space heating or process heat.
The site already has electricity covered, for example by an existing PV array or a low-cost grid supply.
Budget per kWh of heat is the main metric. Solar thermal typically gives the lowest cost per unit of heat.
The climate is cold and you need heat on clear winter days; evacuated tube collectors perform especially well here.
The project is large-scale heating such as solar district heating or industrial process heat.
To estimate collector area, see how to size a solar water heating system.
When to choose PVT panels
PVT panels are usually the better choice when:
Roof space is limited and the building needs both electricity and heat. One PVT field can replace separate PV and thermal arrays.
A heat pump is in the system. PVT supplies electricity to run it and low-temperature heat to raise its efficiency.
The heat demand is low-temperature: swimming pool heating, underfloor heating, DHW preheating, aquaculture, greenhouse and agricultural applications.
The site has high electricity prices or self-consumption targets and wants the most energy from every square metre.
The PV would otherwise run very hot, for example in hot climates or on poorly ventilated roofs, where cooling the cells has real value.
Not sure whether you need PVT or standard PV? Read PVT vs PV: which is right for your project?
Combining PVT and solar thermal on one project
On larger buildings, it does not have to be one or the other. A two-stage design can use both:
Stage 1, PVT: generates electricity and preheats cold incoming water, or feeds a heat pump.
Stage 2, solar thermal: flat plate or evacuated tube collectors lift the water to the final storage temperature.

This approach uses each technology in the temperature range where it works best. It suits hotels, hospitals and residential complexes with both large hot water loads and significant electricity demand. Our PVT hybrid energy systems and solar multi-energy solutions are designed around this kind of integration.
Selection checklist: PVT or solar thermal?
| Question | Points to solar thermal | Points to PVT |
|---|---|---|
| What is the main energy need? | Heat | Electricity and heat |
| What temperature is required? | Above 50°C | Below 40°C, or a heat pump lifts it |
| How much roof area is available? | Enough for separate arrays | Limited |
| Is there a heat pump? | No | Yes or planned |
| Main financial metric? | Lowest cost per kWh of heat | Most total energy per m² |
| Climate? | Cold winters with high heat demand | Mild to hot, or cold with a heat pump |
FAQ
What is the difference between PVT and solar thermal?
A solar thermal collector converts sunlight into heat only. A PVT panel combines PV cells with a heat absorber, so it produces electricity and heat from the same area. Solar thermal delivers more heat at higher temperatures; PVT delivers more total energy per square metre at lower heat temperatures.
Is PVT better than solar thermal?
Neither is better in every case. Solar thermal is usually better for hot water or process heat at 50°C and above. PVT is usually better when roof space is limited and the building needs both electricity and low-temperature heat, especially with a heat pump.
Can PVT panels heat domestic hot water to 60°C?
PVT can contribute to domestic hot water, but works most efficiently at lower temperatures. It is normally used for preheating or as the heat source for a heat pump, which then raises the water to the final temperature.
Why do PVT panels produce more electricity than hot PV panels?
Crystalline silicon cells lose roughly 0.3% to 0.45% of output per 1°C rise in cell temperature. The thermal absorber in a PVT panel removes heat and keeps the cells cooler, recovering part of that lost output.
Can PVT and solar thermal collectors be used in the same project?
Yes. PVT can provide electricity and preheating, while flat plate or evacuated tube collectors reach higher temperatures in a second stage. The right mix depends on the load profile, required temperatures and roof area.
Not sure whether PVT or solar thermal fits your project?
Send us your daily hot water and electricity demand, required temperatures, roof area and location. Our engineers will compare PVT, flat plate and evacuated tube options for your project and recommend the most cost-effective layout.
Ask our engineers


